Design Surface Crackwidth

For Working Stress Design, the check is only applicable to reinforced sections according to the provisions of the Appendix A of IRC21. For Limit States Design, the crack control is per IRC112 Cl. 12.3.6 by checking bar size and bar spacing limits.